Chimney Flashing Repair in Paramount, After the Leak Is Proven

About Chimney Flashing Repair

Inside the Written Scope

Flashing takes the blame for most chimney leaks, so a sectioned hose test comes before any metal work. Where the joint has failed, new step pieces are woven into the roofing and counter flashing is set into a sawn reglet in the brick. The code asks for a cricket on the uphill side once a chimney is wider than thirty inches. A cricket alone runs $475 to $1,065; with all new flashing, $710 to $1,750.

Hose run one face at a time to find the entry
Step pieces lapped into every roofing course
Counter flashing let into a sawn reglet
Crickets framed where width passes thirty inches
Clay and concrete tile lifted and reset
Crumbling brick above the metal rebuilt as well

Proving It Is the Flashing

A ceiling stain next to a chimney has at least four possible sources: the flashing at the roof line, the crown on top, the brick itself taking on rain, or an uncapped flue letting water fall inside. Roofs leak near chimneys too, from a cracked tile or a nail hole a few feet away. Flashing gets the blame most often because it is the part people know about, and replacing it on a guess means some owners pay for new metal and still have a stain after the next storm. We test before we quote. Water goes onto a single zone, say the downhill flashing, and only that zone, for a set time while someone watches the attic or the ceiling for the first drop; then the next zone gets its turn. When the drip appears, we know which part let it in. When the roof is the real source, the written findings point there, and that goes to a roofer.

The shortcuts we find on chimneys around here explain why we rebuild flashing rather than patch it. Counter flashing held to the face with a bead of caulk instead of set into the brick. Step flashing replaced by one long bent strip. Original metal bent back down and reused when the roof was redone. Proper chimney flashing is two layers that do different jobs. The lower layer is a series of short L shaped pieces interleaved with the roofing courses up each side of the chimney, one leg flat on the roof and one standing against the brick. The upper layer is let into a slot sawn in a mortar joint and turned down to cover the standing legs. The two are never fastened to each other, so the roof and the chimney can each move as the house heats, cools and settles without tearing the seal. That is the method we put back.

The Cricket Rule and What It Costs

The residential code adds one more piece on some chimneys: a cricket, a small ridged saddle built on the uphill side so runoff parts around the chimney instead of pooling behind it. The rule applies when the side of the chimney facing up the slope measures more than thirty inches across, unless the chimney sits at the ridge. Many older houses in the Gateway Cities were built with wide chimneys and no cricket, and the pool behind them is where flashing fails first, since water and debris sit against the metal after every storm. If your chimney is that wide and lacks one, the quote includes it with the reason. The cricket alone is $475 to $1,065. Paired with flashing renewed on every side, the price is $710 to $1,750, and that pairing is the usual case, since the edges of a new cricket need new flashing anyway.

The quote also reflects the roof. Composition shingle is the simplest to flash; clay or concrete tile has to be lifted and reset around the new metal without breaking it, which takes longer; a flat roof with a torch down or coated surface needs a different base flashing altogether. We note the roof type, the chimney width and the state of the mortar joints the counter flashing will sit in. If those joints are soft, they get repointed in the same visit, since a slot cut in crumbling mortar will not hold metal for long. Flashing trouble often arrives with a reroof, when the roofer bent the old metal back down or bedded it in mastic. If you are about to reroof, have the chimney flashing done at the same time, and done to the code's two layer method. Leaks that turn out not to be flashing at all have their own page.

Four Habits on Every Elmore Chimney Sweep Job

Clause Beside Defect

Findings carry the NFPA 211 section, code line or listing figure they fail

Level Picked by Reason

A sale, a fuel change or a quake moves the inspection to Level 2

Price Shown First

Published figures where the list has one, a signed scope where it does not

Permit Seen Through

Filing, the inspector visits and the signed card when the job needs one

Related Code-Driven Work

Chimney Sweep

Soot depth measured first, the flue brushed when the standard calls for it, and the spark screen left open to draw.

Rules and scope

Chimney Inspection

The NFPA 211 level matched to your reason for calling, with every defect written next to the rule it breaks.

Rules and scope

Chimney Repair

Each fault classed as fire risk, water entry or plain wear, then repaired under a written scope citing the rule.

Rules and scope

Fireplace Inspection

Hearth depth, mantel gap and firebox wear measured against whichever rulebook applies: the masonry code or the unit's listing.

Rules and scope

Fireplace Repair

Manufacturer parts for listed metal fireboxes, firebrick and refractory mortar for masonry ones, priced on paper before work.

Rules and scope

Chimney Level 2 Inspection

The deeper NFPA 211 level, owed at a sale, an appliance or fuel change, a chimney fire or quake damage.

Rules and scope

Chimney Cap Installation

Spark arrestor caps built to the residential code's mesh and open area numbers, then fitted to your flue and crown.

Rules and scope

Chimney Masonry Repair

Joint mortar picked to stay weaker than the brick, crowns recast with a drip lip, and cracks read for structural movement.

Rules and scope

Chimney Rebuilds

Stacks past repair rebuilt with reinforcing steel and anchors into the framing, under a city permit with staged inspections.

Rules and scope

Fireplace Cleaning

Firebox, grate and doors cleaned so hidden cracks and tight clearances come into view and get recorded.

Rules and scope

Gas Fireplace Cleaning

Annual service that follows your model's own manual, with the outdoor vent cap cleared and carbon monoxide measured.

Rules and scope

Gas Fireplace Repair

Meter tests on the pilot, flame sensor, valve and ignition, with the model's listed part fitted and every joint leak tested.

Rules and scope

Fireplace Remodel

Mantels, surrounds and hearths laid out around clearance figures first, with fuel switches permitted where the city asks.

Rules and scope

Fireplace Inserts

A sealed gas insert, a stainless liner to the chimney top and the gas line, permitted and finaled as one job.

Rules and scope

Pellet Stove Repair

Fuel feed, igniter, fans and safety switches tested in a set order, with the vent run held to the manual's limits.

Rules and scope

Wood Stove Repair

Fresh gaskets, baffle boards and firebrick so the stove controls its air, plus pipe, clearance and floor pad checks.

Rules and scope

Gas Logs

Vented log sets matched to your firebox and flue, the damper locked open as the listing asks, gas valve within reach.

Rules and scope

Chimney Seismic Retrofit

Brick stacks banded, braced back to the roof structure or lightened above the roof, scoped once the masonry is graded.

Rules and scope

Chimney Crown Repair

Small crown cracks closed with an elastomer; failed crowns poured again with an overhang and a break around the flue tile.

Rules and scope

Dryer Vent Cleaning

Lint pulled from the full duct to the outdoor hood, with duct material and run length compared to the code.

Rules and scope

Chimney Liner Installation

Stainless liners sized to the appliance outlet, run the full height of the flue and permitted where required.

Rules and scope

Chimney Leak Repair

Crown, cap, flashing and brick tested one at a time until the real entry point shows, then that point repaired.

Rules and scope

Chimney Waterproofing

A repellent that still lets brick dry out, brushed on once the crown, flashing and mortar have passed.

Rules and scope

Chimney Damper Repair

Seized or warped throat dampers repaired, or a cable operated unit mounted on the flue tile in their place.

Rules and scope

Chimney Chase Cover

Corroded or sagging chase tops replaced in stainless, built to your chase with skirts that shed water past the siding.