Tenant safety at every fireplace, written down unit by unit
Arrange a building visit
Send the property address and a rough count of fireplaces. We call back to plan access.
The safety items we check at each fireplace
A building visit is built around the things that can hurt a tenant, not around cosmetic wear. At every unit we go through the same list, so the records line up and nothing is skipped because a unit was awkward to reach.
- Flue open and drawing, with no nest, debris or collapsed tile visible
- Spark screen in place on the cap and free of holes
- Damper working, so the flue can be opened before a fire
- Gas valve and key in reach, with no smell of gas at the hearth
- Mantel, trim and floor covering at a safe distance from the opening
- CO alarm present and sounding when tested
Carbon monoxide: what we look at and what we record
Carbon monoxide is the risk tenants cannot see or smell. In a fireplace it usually comes from a flue that is blocked, a damper left shut under a gas log set, or a vent that has come apart. Those are the things we look for first.
State law expects working CO alarms in homes with fuel-burning appliances. We note whether an alarm is present in the unit and whether it sounds on test, and we flag any unit where it is missing so you can act on it.
How a building visit runs
You send the property, the number of units with a fireplace and how we get into each one: notice to tenants, a key or a member of your staff. We plan the visit unit by unit and move through the building in one go. Units we cannot reach on the day are listed as missed, so the record never claims more than we saw.
Where a unit needs the camera, such as after a chimney fire or a crack we can see, we say so in that unit's record and quote the Level 2 for that fireplace alone.
Records a manager or a board can file
Each fireplace gets its own dated entry with the unit number, what we checked, what we found and what should happen next. The entries roll up into one building summary. That is the paperwork a board minutes book, a lender or an insurer renewing a policy tends to ask for.
Per-fireplace pricing
The building total follows the number of fireplaces. Camera work and sweeping apply only where a unit needs them.
- Safety check, per fireplace
- $58
- Camera inspection for any unit that needs one
- $415
- Sweeping a flue that is due
- from $445
Questions from managers and boards
How are tenants affected on the day?
Briefly. Each check is short, nothing in the unit is opened up, and drop cloths go down at the hearth. Most managers give written notice and send staff with keys; a unit we cannot reach is listed as missed.
What happens if a unit is unsafe to use?
We tell you on the day, mark it clearly in that unit's record and say what has to be fixed before the fireplace is lit again.
Do you check gas fireplaces as well as wood?
Yes. For a gas unit the visit covers the pilot, the shutoff valve, the vent run and the glass front, and we write down any gas smell or soot that suggests a burner fault.
Can the records go straight to our board or insurer?
Yes. Name who should receive them when you book, and they get the building summary and the unit entries.
How often should a building be checked?
NFPA 211 expects chimneys to be inspected once a year. Many managers book the visit before the cool months, when tenants start using fireplaces.
Fireplaces across a building or a portfolio?
Start on our contact page with the property and a fireplace count. We will call to plan access and give you the per-fireplace total.